Type 3 surge protection plug - PLT-SEC-T3-230-P-UT/PT

คุณสมบัติสินค้า:

SKU : 2907923

Replacement plug for type 2/3 surge protection from the PLT-SEC-…-UT/PT product series. Nominal voltage 230 V.

แบรนด์ : Phoenix Contact

Share

Type 3 surge protection plug - PLT-SEC-T3-230-P-UT/PT
2907923


Replacement plug for type 2/3 surge protection from the PLT-SEC-…-UT/PT product series. Nominal voltage 230 V.


IEC power supply system: TN-S / TT
Type: Male
Product type: Replacement plug
Product family: SEC Family
Number of positions: 2
Surge protection fault message: optical

 
Insulation characteristics

Overvoltage category: III
Pollution degree:  2
IEC test classification: II / III
T2 / T3
EN type: T2 / T3
Number of ports: One

 
Protective circuit
Mode of protection: L-N / L-PE / N-PE
Direction of action: 1L-N & N-PE
Nominal voltage UN: 240 V AC (TN-S) /240 V AC (TT)
Nominal frequency fN: 0 Hz (60 Hz)
Maximum continuous voltage UC: 264 V AC
Residual current IPE: ≤ 5 µA
Standby power consumption PC: ≤ 26.4 mVA (at UREF) / ≤ 26.4 mVA (at UC)
Reference test voltage UREF: 264 V AC
Nominal discharge current In (8/20) µs: 5 kA
Maximum discharge current Imax (8/20) µs: 10 kA
Combination wave UOC: 6 kV
Voltage protection level Up (L-N): ≤ 1.25 kV (at UOC)  / ≤ 1.4 kV (at In)
Voltage protection level Up (L-PE): ≤ 1.4 kV
Voltage protection level Up (N-PE): ≤ 1.4 kV
TOV behavior at UT (L-N): 400 V AC (5 s / withstand mode) / 457 V AC (120 min / safe failure mode)
TOV behavior at UT (L-PE): 457 V AC (5 s / withstand mode) / 457 V AC (120 min / withstand mode) / 1464 V AC (200 ms / safe failure mode)
TOV behavior at UT (N-PE): 1200 V AC (200 ms / safe failure mode)
Response time tA (L-N): ≤ 25 ns
Response time tA (L-PE): ≤ 100 ns
Response time tA (N-PE): ≤ 100 ns
Short-circuit current rating ISCCR: 10 kA AC
Max. backup fuse with branch wiring: 32 A (gG / B / C)

 
Additional technical data
Short-circuit current rating ISCCR: 0.25 kA DC (Without additional backup fuse in the DC branch wiring) / 5 kA DC (for 20 A gG / B backup fuse)
Residual voltage Ures (L-N): ≤ 1.15 kV (at 2 kA) / ≤ 1.25 kV (at 3 kA) / ≤ 1.1 kV (at UOC = 4 kV)
Residual voltage Ures (L-PE): ≤ 1.1 kV (at 2 kA) / ≤ 1.1 kV (at 3 kA) / ≤ 1.2 kV (at UOC = 4 kV)
Residual voltage Ures (N-PE): ≤ 1.1 kV (at 2 kA) / ≤ 1.1 kV (at 3 kA) / ≤ 1.2 kV (at UOC = 4 kV)
Maximum continuous voltage UC: 275 V AC / 240 V DC
Mode of protection: (DC+) - (DC-) / (DC+/DC-) - PE
IEC test classification (in accordance with IEC 61643-21):  D1
Impulse durability (wire-wire): D1 - 500 A
Impulse durability (line-earth): D1 - 500 A
Pulse discharge current Iimp (10/350) µs (line-line) : 0.5 kA
Pulse discharge current Iimp (10/350) µs (line-earth) : 0.5 kA

 
Ambient conditions
Degree of protection: IP20
Ambient temperature (operation) : -40 °C ... 80 °C
Ambient temperature (storage/transport) :  -40 °C ... 80 °C
Altitude ≤ 6000 m (amsl (above mean sea level))
Permissible humidity (operation) :  5 % ... 95 %


UL specifications
Maximum continuous operating voltage MCOV: 264 V AC / 240 V DC
Nominal discharge current In: 5 kA
Mode of protection: L-N / L-G / N-G / (DC+) - (DC-) / (DC+) – G / (DC-) - G
Nominal voltage: 240 V DC
Power distribution system: Single phase  / DC
Nominal frequency: 50/60 Hz
Measured limiting voltage MLV (L-N) : 1150 V
Measured limiting voltage MLV (L-G) : 1180 V
Measured limiting voltage MLV (N-G) : 1180 V
SPD Type: 4CA

 
Download datasheet